Below table presents connection method for 6R80 transmission and GCU standalone.

Table 1.
6R80 plug HTG GCU pin description wire gauge
1 FREQ_in1 (A3) shielding optional 0,35mm2 (22AWG)
2 NOT USED    
3 PWR_out1 (H1)   0,75mm2 (19AWG)
4 FREQ_in3 (B3) shielding optional 0,35mm2 (22AWG)
5 sGND (L2)   0,35mm2 (22AWG)
6 AN_in1 (C1) 2k2 pullup to 5v 0,35mm2 (22AWG)
7 +12v MAIN join with M3, M4. 15A fuse all together 1mm2 (18AWG)
8 PWR_out2 (H2)   0,75mm2 (19AWG)
9 PWR_out3 (H3)   0,75mm2 (19AWG)
10 PWR_out4 (H4)   0,75mm2 (19AWG)
11 sGND (L2)   0,35mm2 (22AWG)
12 +12v MAIN join with M3, M4. 15A fuse all together 1mm2 (18AWG)
13 PWR_out5 (J1)   0,75mm2 (19AWG)
14 PWR_out6 (J2)   0,75mm2 (19AWG)
15 FREQ_in2 (A4)   0,35mm2 (22AWG), shielded
16 PWR_out7 (J3)   0,75mm2 (19AWG)